MC7800, MC7800A, LM340, LM340A Series
4
MOTOROLA ANALOG IC DEVICE DATA
ELECTRICAL CHARACTERISTICS (continued)
(Vin = 10 V, IO = 1.0 A, TJ = Tlow to Thigh [Note 1], unless otherwise noted.)
MC7805AC/LM340AT–5
Characteristic
Symbol
Min
Typ
Max
Unit
Output Noise Voltage (TA = 25
°
C)
10 Hz
≤
f
≤
100 kHz
Vn
–
10
–
μ
V/VO
Output Resistance (f = 1.0 kHz)
rO
ISC
–
0.9
–
m
Short Circuit Current Limit (TA = 25
°
C)
Vin = 35 Vdc
Peak Output Current (TJ = 25
°
C)
Average Temperature Coefficient of Output Voltage
–
0.2
–
A
Imax
TCVO
–
2.2
–
A
–
–0.3
–
mV/
°
C
NOTES:
1.Tlow = –40
°
C for MC78XXAC, C, LM340AT–XX, LM340T–XX
2.Load and line regulation are specified at constant junction temperature. Changes in VO due to heating effects must be taken into account
separately. Pulse testing with low duty cycle is used.
Thigh = +125
°
C for MC78XXAC, C, LM340AT–XX, LM340T–XX
ELECTRICAL CHARACTERISTICS
(Vin = 11 V, IO = 500 mA, TJ = Tlow to Thigh [Note 1], unless otherwise noted.)
MC7806C
Characteristic
Symbol
Min
Typ
Max
Unit
Output Voltage (TJ = 25
°
C)
Output Voltage (5.0 mA
≤
IO
≤
1.0 A, PD
≤
15 W)
8.0 Vdc
≤
Vin
≤
21 Vdc
9.0 Vdc
≤
Vin
≤
21 Vdc
Line Regulation, TJ = 25
°
C (Note 2)
8.0 Vdc
≤
Vin
≤
25 Vdc
9.0 Vdc
≤
Vin
≤
13 Vdc
Load Regulation, TJ = 25
°
C (Note 2)
5.0 mA
≤
IO
≤
1.5 A
Quiescent Current (TJ = 25
°
C)
Quiescent Current Change
8.0 Vdc
≤
Vin
≤
25 Vdc
5.0 mA
≤
IO
≤
1.0 A
Ripple Rejection
9.0 Vdc
≤
Vin
≤
19 Vdc, f = 120 Hz
Dropout Voltage (IO = 1.0 A, TJ = 25
°
C)
Output Noise Voltage (TA = 25
°
C)
10 Hz
≤
f
≤
100 kHz
VO
VO
5.75
6.0
6.25
Vdc
Vdc
5.7
–
6.0
–
6.3
–
Regline
mV
–
–
0.5
0.8
24
12
Regload
–
1.3
30
mV
IB
IB
–
3.3
8.0
mA
mA
–
–
0.3
0.08
1.3
0.5
RR
58
65
–
dB
VI – VO
Vn
–
2.0
–
Vdc
–
10
–
μ
V/VO
Output Resistance f = 1.0 kHz
rO
ISC
–
0.9
–
m
Short Circuit Current Limit (TA = 25
°
C)
Vin = 35 Vdc
Peak Output Current (TJ = 25
°
C)
Average Temperature Coefficient of Output Voltage
–
0.2
–
A
Imax
TCVO
–
2.2
–
A
–
–0.3
–
mV/
°
C
NOTES:
1.Tlow = –40
°
C for MC78XXAC, C Thigh = +125
°
C for MC78XXAC, C
2.Load and line regulation are specified at constant junction temperature. Changes in VO due to heating effects must be taken into account
separately. Pulse testing with low duty cycle is used.