CATALOG 2001 Page 17 ID: 0198
Illustration
Description
Voltage
ELASTIMOLD
Notes
(not to scale)
Class
Part Number
WINDOW-OP
15kV
655ETP-W0X-DRG
N1,3,4,5,
CONNECTOR
Use Tables W7 and X6
6,13
KIT
25kV
K655ETP-W0X-DRG
Use Tables W7 and X6
35kV
755ETP-W0X-DRG
Use Tables W9 and X6
STICK-OP
15kV
655LRTP-W0X-DRG
N2,3,4,5,
CONNECTOR
Use Tables W7 and X6
8,13
KIT
25kV
K655LRTP-W0X-DRG
Use Tables W7 and X6
35kV
755LRTP-W0X-DRG
Use Tables W9 and X6
WINDOW-OP
15kV
650ETP
N4,15
Loadbreak
25kV
K650ETP
N4,15
Reducing
35kV
750ETP
N4,15
Tap Plug
STICK-OP
15kV
650LRTPA3
N3,4
Loadbreak
25kV
K650LRTPA2
Reducing
35kV
750LRTPA2
Tap Plug
STICK-OP
15kV
650BEA3
N3,4
Bushing
25kV
K650BEA2
Adapter
35kV
750BEA2
Compression
ALL
03700X
N6
Lug
Use Tables X6
WINDOW-OP
ALL
03702X
N7
Use Tables X6
Threaded
ALL
03600X
N8
Compression
Use Tables X6
Lug
ALL
03602X
N9
STICK-OP
Use Tables X6
WINDOW-OP
15/25kV 655CK-W0X
N5
Size Sensitive Kit
Use Tables W7 and X6
(Cable Adapter
35kV
755CK-W0X
N5
& Lug)
Use Tables W9 and X6
STICK-OP
15/25kV 655TCK-W0X
N5
Size Sensitive Kit
Use Tables W7 and X6
(Cable Adapter
35kV
755TCK-W0X
N5
& Threaded Lug)
Use Tables W9 and X6
Extraction Tool
ALL
600ET
N3,10
Grounding
15kV
160GLR
Elbow
25kV
370GLR
N14
(1/0 AWG x 6'
35kV
370GLR
N14
Ground Lead)
Test Rod
ALL
370TR
Assembly Tool
ALL
600AT
N3
(Stick-Op)
Assembly Tool
ALL
600ATM
N15
(Window-Op)
STICK-OP
15kV
650STICK-OK
N11
OPERATING
25kV
K650STICK-OK
N11
KIT
35kV
750STICK-OK
N11
WINDOW-OP
15kV
650WINDOW-OK
N12
OPERATING
25kV
K650WINDOW-OK
N12
KIT
35kV
750WINDOW-OK
N12
N1. Window-Op Kit includes: insulated cap; Window-Op reducing tap plug;
600 Series elbow housing; cable adapter; and 0370 style compression
lug.
N2. Stick-Op Kit includes insulated cap; Stick-Op Loadbreak reducing tap
plug; 600A Elbow Housing; cable adapter; and threaded 0360 style
compression lug.
N3. 600AT assembly tool required for operation and/or installation.
N4. For 900 Amp ratings, substitute 675 for 650 and 655; 676 for 656; K675
for K650 and K655; K676 for K656; 775 for 750 and 755; 776 for 756
and 2X for 0X in the part number. The 900 Amp rating requires copper
current-carrying connector components and copper conductor cable.
N5. Add suffix symbol from page 29 to include cable shield grounding kit
and/or cable jacket sealing kit.
N6. Aluminum lug for use on aluminum or copper conductors. DO NOT
substitute threaded 03600X lug.
N7. Copper lug for use on COPPER CONDUCTOR ONLY. DO NOT
substitute 03602X threaded lug.
N8. Threaded aluminum lug (Stick-Op only) for use on copper or aluminum
conductors. DO NOT substitute unthreaded 03700X lugs. DO NOT use
with 675, 676, K675, K676, 775 or 776 part numbers.
N9. Threaded copper lug (Stick-Op only) for use on copper conductors only.
DO NOT substitute unthreaded 03702X lugs.
N10. Required to disassemble Stick-Op loadbreak reducing tap plug from the
threaded compression lug and 600 Series elbow after the shear-pin is
broken during assembly.
N11. Stick-Op Operating Kit includes accessories that enable visible break
direct testing, isolation, and grounding functions to be performed. Kit
includes: 3-insulated parking bushings; 3-grounding elbows; 3-
600DB/200LB bushing/elbow adapters; 1-assembly tool; 1-test rod;
1-carry case; l-lubricant; 1-instructions.
N12. Window-Op Operating Kit includes accessories that enable visible
grounding and direct testing functions to be performed. Kit includes:
3-grounding elbows; 1-test rod; 1-carry case; 1-lubricant; 1-instructions.
N13. 600 Series Elbows and Straight Receptacles with IEEE Std. 386
capacitive test points are available by substituting 656 for 655; K656 for
K655; K676 for K675; 756 for 755; 676 for 675; K676 for K675 and 776
for 775 in the part number.
N14. Rated for both 25kV and 35kV applications.
N15. 600ATM assembly tool required for Window-Op assembly.
STICK-OP & WINDOW-OP
Refer to the W and X tables on pages 32 and 33 for sizing to cable
insulation diameter and conductor size.
For cable shield adapters and jacket seals, see page 28.
Part numbers that contain
the letters W or X are size
sensitive. To complete the
part number, refer to the
W or X tables indicated.