![](http://datasheet.mmic.net.cn/230000/700FS-Y2DA40_datasheet_15556350/700FS-Y2DA40_4.png)
4
700
–
FS Electronic High Performance Timing Relays
Technical Data, Continued
See 700–FS Tining Charts
SPDT
DPDT
Cat. No.
Cat. No.
(G) Flasher (Repeat Cycle Starting with Pause)
The output contact remains in the shelf state until the time delay is completed. When
the time delay is completed, the contact changes state. This cycle continues until the
power is removed.
700-FSG3KU23
700-FSG3LU23
700-FSG3 Z12
700-FSG3 U23
—
(I) On-delay pulse generator
The output contact changes state when the time delay is completed. After 0.5s the
contact opens.
700-FSI3KU23
700-FSI3LU23
700-FSI3 Z12
700-FSI3 U23
700-FSJ3KU23
700-FSJ3LU23
700-FSJ3 Z12
700-FSJ3 U23
700-FSK3KU23
700-FSK3LU23
700-FSK3 Z12
700-FSK3 U23
—
(J) On-delay (pulse controlled)
(Mn. Pulse AC 50ms – DC 30ms)
Input power must be supplied to termnal (A1/A2) continuously. When swtch “S” is closed,
the time delay begins. The output contact changes state at the end of the time delay. The
output contact returns to shelf state when the power to (A1/A2) is removed.
(K) One shot / watch dog (pulse controlled)
(Min. Pulse AC 50ms
–
DC 30ms)
Input power must be supplied to termnal (A1/A2) continuously. When switch “S” is
closed, the output contact changes state. The output contact will open when switch “S”
is open for longer than the time setting.
(L) Pulse converter
(Mn. Pulse AC 50ms – DC 30ms)
Input power must be supplied to termnal (A1/A2) continuously. When swtch “S” is closed,
the output contact changes state. When the time delay is completed, the output contact
returns to shelf state. The time “t” is not influenced by the duration of the control pulse.
—
—
700-FSL3KU23
700-FSL3LU23
700-FSL3 Z12
700-FSL3 U23
—
Mono-Time Ranges
Complete the Cat. No. with mono-time range identification
Time ranges
0.05...1 s
A
0.15...3 s
B
0.5...10 s
C
1.5...30 s
D
0.05...1 mn
E
0.15...3 mn
F
Time ranges
0.5...10 mn
G
1.5...30 mn
H
0.05...1 h
I
0.15...3 h
J
0.5...10 h
K
3.0...60 h
L
0.05 s...60 h
U
700
–
FSH Special Function Flasher (repeat cycle starting with pulse or pause) Timing Relays
Description
SPDT
Up
Down
Switch
FSH3U
t
2
Setting
t
1
Setting
Separate Range Settings
1 Range Setting
700–FSH3U
700–FSH3V
See 700–FS Timing Charts
Supply voltages (A1/A2)
Z12
12 VDC
U23
24...48 VDC
24...240 VAC, 50/60 Hz
Multi-time setting ranges
U 0.05s...60 h (1 Range Setting)
V
0.05s...60 h (2 Range Settings)
(1s)
0.05...1 s
(3s)
0.15...3 s
(10s)
0.5...10 s
(1mn)
0.05...1 mn
(3mn)
0.15...3 mn
(10mn)
0.5...10 mn
(1h)
0.05...1 h
(3h)
0.15...3 h
(10h)
0.5...10 h
(60h)
3...60 h
Cat. No.
10h
(H) Flasher (repeat cycle starting with pulse or pause)
The repeat cycle timer permts different settings for on and off times.
The following operating modes are possible:
– Oscillating mode; repeat cycle starts with voltage applied at A1 and B1, and continues to repeat until voltage is off.
– One cycle mode; started by energizing B1 with voltage on A1 and A2.
– Output starts wth pulse or pause (swtch
Up or Down).
– 700–FSH3U provides (1) range setting for t
1
and t
2
.
– 700–FSH3V provides (2) range settings for t
1
and t
2
.
Supply voltage controlled, Oscillating Mode starting with pause – Switch
is Up
Supply voltage controlled, Oscillating Mode starting with pulse – Switch
is Down
Pulse controlled, output starts with pulse (Mn. Pulse AC 50ms – DC 30ms) – Switch
is Up
Pulse controlled, output starts with pulse (Mn. Pulse AC 50ms – DC 30ms) – Switch
is Down
700-FSH3UU23
700-FSH3VU23
700-FSH3UZ12
700-FSH3VZ12
NOTE:
If B1 is pulsed, a one full time cycle consisting of t
1
and t
2
is completed.