H04-004-03
22
MS6M 0675
a
19
a
18. ReliabilityTest Items
Test
cate-
gories
Test items
Test methods and conditions
Reference
norms
EIAJ
ED-4701
Number
of sample
Accept-
ance
number
1 Terminal strength
端子強度
(Pull test)
2 Mounting Strength
締付け強度
3 Vibration
振動
Pull force
: 40 N (main terminal)
10 N (control terminal)
: 10 ±1 sec.
: 2.5 ~ 3.5 N
m (M5)
: 10 ±1 sec.
: 10
~500 Hz
: 15 min.
: 100 m/s
2
: Each X,Y,Z axis
: 6 hr. (2hr./direction)
Test Method 401
Method
Ⅰ
5
( 1 : 0 )
Test time
Screwtorque
Test time
Range of frequency
Sweeping time
Acceleration
Sweeping direction
Test time
Maximum acceleration : 5000 m/s
2
Pulse width
Direction
Test time
Solder temp.
Immersion duration
Test time
Each terminal should be Immersed in solder
within 1~1.5mm from the body.
Solder temp.
Immersion time
Test time
Each terminal should be Immersed in solder
within 1~1.5mm from the body.
Storage temp.
Test duration
Storage temp.
Test duration
Storage temp.
Relative humidity
Test duration
Test temp.
Atmospheric pressure : 1.7x10
5
Pa
プレッシャークッカー
Test humidity
Test duration
5 Temperature
Test temp.
cycle
溫度サイクル
Dwell time
Test Method 402
method
Ⅱ
Test Method 403
Condition code B
5
( 1 : 0 )
5
( 1 : 0 )
4 Shock
衝撃
Test Method 404
Condition code B
5
( 1 : 0 )
1.0 ms
: Each X,Y,Z axis
: 3 times/direction
: 235 ±5
℃
: 5.0 ±0.5 sec.
: 1 time
5 Solderabitlity
はんだ付け性
Test Method 303
Condition code A
5
( 1 : 0 )
6 Resistance to
soldering heat
はんだ耐熱性
: 260 ±5
℃
: 10 ±1sec.
: 1 time
Test Method 302
Condition code A
5
( 1 : 0 )
1 High temperature
storage
高溫保存
2 Lowtemperature
storage
低溫保存
3 Temperature
humidity storage
高溫高濕保存
4 Unsaturated
pressure cooker
: 125 ±5
℃
: 1000 hr.
: -40 ±5
℃
: 1000 hr.
: 85 ±2
℃
: 85 ±5%
: 1000hr.
: 120
±
2
℃
Test Method 201
5
( 1 : 0 )
Test Method 202
5
( 1 : 0 )
Test Method 103
Test code C
5
( 1 : 0 )
Test Method 103
Test code E
5
( 1 : 0 )
: 85
±
5%
: 96 hr.
: Minimum storage temp. -40
±
5
℃
Maximum storage temp. 125
±
5
℃
Normal temp.
: Tmin ~ TN ~ Tmax ~ TN
1hr.
0.5hr. 1hr.
: 100 cycles
Test Method 105
5
( 1 : 0 )
5 ~ 35
℃
0.5hr.
Number of cycles
6 Thermal shock
熱衝撃
+0
Test Method 307
method
Ⅰ
Condition code A
5
( 1 : 0 )
Test temp.
: High temp. side 100
-5
℃
+5
Low temp. side
: Pure water (running water)
: 5 min. par each temp.
: 10 sec.
: 10 cycles
0
-0
℃
Fluid used
Dipping time
Transfer time
Number of cycles
M
E