![](http://datasheet.mmic.net.cn/230000/52202_datasheet_15553119/52202_2.png)
4
Subject to reasonable modifications due to technical advances.
Pepperl+Fuchs Group Tel.: Germany (06 21) 7 76-0 USA (330) 4 25 35 55 Singapore 7 79 90 91 Internet http://www.pepperl-fuchs.com
Copyright Pepperl+Fuchs, Printed in Germany
Hinweise
Note
Model number
Characteristic curves/
Additional information
UCC1000-30GM-E6-V1
1.2
1.4
1.6
1.8
2.0
2.2
2.4
2.6
0.0
0.2
0.4
0.6
0.8
1.0
Characteristic response curves
Distance [m]
Angle [degrees]
Curve 1: flat plate 100 mm x 100 mm
Curve 2: round bar, 25 mm
1
20
10
-0
-10
-20
90
80
70
60
50
40
30
2
E2
E3
A1
A2
LED
yellow
Dual-LED
green/red
LED
yellow
Switch output 1
"Power on"/Disturbance
Switch output 2
LED-Window
Notes:
This ultrasonic sensor features a four-pole temperature/TEACH-IN plug that can be
connected in four different positions. These have the following significance.
Description of the TEACH-IN procedure:
- Remove temperature plug
- Cut and restore supply voltage (e.g. by removing and replacing unit plug)
TEACH-IN of switching points 1 and 2:
- Set object to desired switching point
- Connect TEACH-IN plug in pos. A1 or A2
- Green LED flashes when object detected, red LED flashes when no object detec-
ted
- Pull the plug (the current object position is taught and stored when the plug is re-
moved!)
TEACH-IN of switching function:
- Connect TEACH-IN plug in pos. E2/E3
- The yellow LED indicates the switching function
E2: 2 independent switching points (NO)
E3: window function: switch output 1 NO, switch output 2 NC
- Pull the plug when the desired function is activated, otherwise reconnect the
TEACH-IN plug in pos. E2/E3
- Pull plug
Completing the TEACH-IN procedure:
- Connect TEACH-IN plug in pos. T. Temperature compensation is now activated.
Note:
If the temperature plug has not been plugged in within 5 minutes, the sensor will
return to normal mode without temperature compensation.
Plug position
A1
A2
E2/E3
T
Meaning
Teach switching point A1
Teach switching point A2
Switching: 2 independent switching positions/window function
Temperature compensation
Displays depending on position of tem-
perature/
TEACH-IN plug position
Teach switching point output A1
Object detected
No object detected
Teach switching point output A2
Object detected
No object detected
TEACH-IN of switch output functions:
E2: 2 independent switching positions
E3: window function
Normal mode, temperature compensated On
Green
dual LED
Red dual
LED
Yellow
LED
A1/E2
Yellow
LED
A2/E3
Flashing
Off
Off
Flashing
Flashing
Flashing
Off
Off
Flashing
Off
Off
Flashing
Off
Off
Flashing
Flashing
On
On
Off
Off
Off
Flashing
Off
Swit-
ching
state A1
Swit-
ching
state A1
Previous
state
Off
Flashing
Swit-
ching
state A2
Swit-
ching
state A2
Previous
state
Plug pulled or shorted
Off
On
Interference (e.g. compressed air)
Off
Flashing
Programmed switching output function
Position of insert
Switch output functions
Switch point 1
Switch point 2
A 1 (N.O.)
Switch output 1
A 2 (N.O.)
Switch output 2
A 1 (N.O.)
Switch output 1
A2 (N.C.)
Switch output 2
E2