12
8
4
0
2
4
8
10
6
20
40
60
80
Load Current [Arms]
Max Ambient Temp. [C]
Power
Dissipation
110
115
120
Base
Plate
Temp
[C]
10A
9C/W
5C/W
3C/W
7C/W
NO HEATSINK
30
20
10
25
15
5
0
5
10
20
25
15
20
40
60
80
Load Current [Arms]
Max Ambient Temp. [C]
Power
Dissipation
95
120
Base
Plate
Temp
[C]
25A
1C/W
100
110
3C/W
NO HEATSINK
60
40
20
0
10
20
40
50
30
20
40
60
80
Load Current [Arms]
Max Ambient Temp. [C]
Power
Dissipation
90
Base
Plate
Temp
[C]
50A
2C/W
1C/W
.5C/W
100
110
120
1.5C/W
NO HEATSINK
120
80
40
0
15
30
60
75
45
20
40
60
80
Load Current [Arms]
Max Ambient Temp. [C]
Power
Dissipation
100
110
120
Base
Plate
Temp
[C]
75A
.5C/W
95
1C/W
120
80
40
0
20
40
80
0
60
20
40
60
80
Load Current [Arms]
Max Ambient Temp. [C]
Power
Dissipation
100
110
120
Base
Plate
Temp
[C]
90A
1C/W
.4C/W
.2C/W
90
.5C/W
2C/W
.3C/W
Series 1
10-90Amp 120, 240 Vac AC Output
CURRENT DERATING CURVES
FastFax Document No.151
SERIES1.032698, PAGE 3 OF 3
1998 CRYDOM CORP, Specifications subject to change without notice.
For recommended applications and more information contact:
USA: (800) 8 CRYDOM (800) 827-9366 (619) 715-7200 fax (619) 715-7280
Crydom Corp, 9525 Chesapeake Drive, San Diego, CA 92123 e-mail: sales@crydom.com
WEB SITE: http://www.crydom.com FASTFAX Product Information: (888) 267-9191
UK: (44)1202 812300 fax (44)1202 812340 Crydom International Ltd., 85, Condor Close,
Woolsbridge Industrial Estate, Three-Legged Cross. Wimborne, Dorset, England BH21 6SU
GERMANY: (49) (0)6874 182580 fax (49)(0)6874 182585 Crydom GmbH,
Gewerbegebiet Im Schachen, D-66687 Nunkirchen, Germany e-mail: vertrieb@crydom.com