Function of Each Parameter
15
Note:
For n09, n11, and n12, the unit of setting is as follows:
Values will be set in 0.1-Hz increments if the frequency is
less than 100 Hz and 1-Hz increments if the frequency is
100 Hz or greater.
Output
voltage (V)
Frequency
(Hz)
Note:
1. Set the parameters so that the following condition will
be satisfied.
n14
n12 < n11
n09
2. The value set in n13 will be ignored if parameters n14
and n12 are the same in value.
n10
n13
n15
Acceleration/Deceleration Time Settings
(n16 to n19)
The acceleration time is the time required to go from 0% to 100%
of the maximum frequency and the deceleration time is the time
required to go from 100% to 0% of the maximum frequency. The
actual acceleration or deceleration time is obtained from the fol-
lowing formula.
Acceleration/Deceleration time =
(Acceleration/Deceleration time set value)
×
(Frequency refer-
ence value)
÷
(Max. frequency)
Value
Name
Setting
range
Unit of
setting
Default
set-
tings
10.0
10.0
10.0
10.0
n16
n17
n18
n19
Acceleration time 1
Deceleration Time 1
Acceleration time 2
Deceleration Time 2
0.0 to 999
0.1 s
S-shape Acceleration/Deceleration Characteristic
(n20)
Any one of three S-shape acceleration/deceleration times (0.2,
0.5, and 1.0 s) is selectable.
Value
Description
0
No S-shape acceleration/deceleration characteristic
(Trapezoidal acceleration/deceleration)
S-shape acceleration/deceleration characteristic time is 0.2 s
1
2
S-shape acceleration/deceleration characteristic time is 0.5 s
3
S-shape acceleration/deceleration characteristic time is 1.0 s
Note:
When the S-shape acceleration/deceleration character-
istic time is set, the acceleration and deceleration times
will be lengthened according to the S-shape at the begin-
ning and end of acceleration/deceleration.
Setting the Frequency References 1 to 8 and the
Inching Frequency Command (n21 to n28 and n29)
Set internal frequency references.
Value
Name
Setting
range
Unit of
setting
Default
set-
tings
6.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
6.0
n21
n22
n23
n24
n25
n26
n27
n28
n29
Frequency reference 1
Frequency reference 2
Frequency reference 3
Frequency reference 4
Frequency reference 5
Frequency reference 6
Frequency reference 7
Frequency reference 8
Inching frequency com-
mand
0.0 to max.
frequency
0.1 Hz
(see note
1)
Note:
1. Values will be set in 0.1-Hz increments if the frequency is less
than 100 Hz and 1-Hz increments if the frequency is 100 Hz
or over.
2. Frequency reference 1 is enabled with n03 for frequency ref-
erence selection set to 1. (Remote mode)
3. Frequency references 1 to 8 are enabled by setting multi-
step speed references 1, 2, and 3 in n36 to n39 for multi-func-
tion input. Refer to the following table for the relationship be-
tween multi-step speed references 1 to 3 and frequency ref-
erences 1 to 8.
Frequency
reference
Frequency
reference 1
Frequency
reference 2
Frequency
reference 3
Frequency
reference 4
Frequency
reference 5
Frequency
reference 6
Frequency
reference 7
Frequency
reference 8
Multi-step speed
reference 1
OFF
Multi-step speed
reference 2
OFF
Multi-step speed
reference 3
OFF
ON
OFF
OFF
OFF
ON
OFF
ON
ON
OFF
OFF
OFF
ON
ON
OFF
ON
OFF
ON
ON
ON
ON
ON
Note:
1.
“
ON
”
and
“
OFF
”
represent
“
input ON
”
and
“
input OFF,
”
re-
spectively.
2. Inching frequency commands take precedence over multi-
step speed references.