28F6408W30, 28F3204W30, 28F320W30, 28F640W30
Preliminary
73
Table C9. Protection Register Information
(1)
Length
P = 39h
(P+E)h
Table C10. Burst Read Information
(1)
Table C11. Partition and Erase-block Region Information
Bottom
Top
(1)
(1)
Description
Hex
Code Value
--01
(Optional flash features and commands)
Number of Protection register fields in JEDEC ID space.
“
00h,
”
 indicates that 256 protection fields are available
Protection Field 1: Protection Description
This field describes user-available One Time Programmable 
(OTP) Protection register bytes. Some are pre-programmed  
with device-unique serial numbers. Others are user 
programmable. Bits 0
–
15 point to the Protection register Lock 
byte, the section
’
s first byte. The following bytes are factory 
pre-programmed and user-programmable.
Add.
47:
1
1
(P+F)h
(P+10)h
(P+11)h
(P+12)h
4
48:
49:
4A:
4B:
--80
--00
--03
--03
80h
00h
8 byte
8 byte
bits 0
–
7 = Lock/bytes Jedec-plane physical low address
bits 8
–
15 = Lock/bytes Jedec-plane physical high address
bits 16
–
23 = 
“
n
”
 such that 2n = factory pre-programmed bytes
bits 24
–
31 = 
“
n
”
 such that 2n = user programmable bytes
Length
Description
Hex
Code Value
--03
P = 39h
(P+13)h
(Optional flash features and commands)
Page Mode Read capability
bits 0
–
7 = 
“
n
”
 such that 2
n
 HEX value represents the number of 
   read-page bytes. See offset 28h for device word width to 
   determine page-mode data output width.  00h indicates no 
Add.
4C:
1
8 byte
(P+14)h
1
Number of synchronous mode read configuration fields that 
follow. 00h indicates no burst capability.
Synchronous mode read capability configuration 1
   Bits 3
–
7 = Reserved
   bits 0
–
2 
“
n
”
 such that 2
n+1
 HEX value represents the 
   maximum number of continuous synchronous reads when 
   the device is configured for its maximum word width. A value 
   of  07h indicates that the device is capable of continuous 
   linear bursts that will output data until the internal burst 
   counter reaches the end of the device
’
s burstable address 
   space. This field
’
s 3-bit value can be written directly to the 
   Read Configuration Register bits 0
–
2 if the device is 
   configured for its maximum word width. See offset 28h for 
4D:
--03
3
(P+15)h
1
4E:
--01
4
(P+16)h
(P+17)h
1
1
Synchronous mode read capability configuration 2
Synchronous mode read capability configuration 3
4F:
50:
--02
--07
8
Cont
See table below
Address
Len
Bot
1
51:
Description
P = 39h
(P+18)h
P = 39h
(P+18)h Number of device hardware-partition regions within the device.
   x = 0: a single hardware partition device (no fields follow).
   x specifies the number of device partition regions containing 
   one or more contiguous erase block regions.
(Optional flash features and commands)
Top
51: