225CNQ015 Series
PD-2.294 rev. A
12/97
2
www.irf.com
V
FM
Max. Forward Voltage Drop
(Per Leg) * See Fig. 1
0.38
0.49
0.32
0.42
40
2000
1780
1080
7700
7.0
10,000
V
V
V
V
@ 110A
@ 220A
@ 110A
@ 220A
T
J
= 25 °C
T
J
= 125 °C
T
J
= 100 °C
T
J
= 100 °C
V
R
= 5V
DC
, (test signal range 100Khz to 1Mhz) 25°C
From top of terminal hole to mounting plane
(1)
I
RM
Max. Reverse Leakage Current
(Per Leg) * See Fig. 2
mA
mA
mA
mA
pF
nH
V/ μs
(1)
C
T
L
S
dv/dt Max. Voltage Rate of Change
(Rated V
R
)
Max. Junction Capacitance (Per Leg)
Typical Series Inductance (Per Leg)
Part number
Max.
DC Reverse Voltage (V)
V
RWM
Max.
Working Peak Reverse Voltage (V)
Absolute Maximum Ratings
225CNQ015
V
R
Voltage Ratings
I
F(AV)
Max. Average Forward Current
* See Fig. 5
I
FSM
Surge Current (Per Leg) * See Fig. 7
220
A
50% duty cycle @ T
C
= 74 °C, rectangular wave form
Max. Peak One Cycle Non-Repetitive
10,800
5μs Sine or 3μs Rect. pulse
1700
9
10ms Sine or 6ms Rect. pulse
T
J
= 25 °C, I
AS
= 2 Amps, L = 4.5 mH
E
AS
(Per Leg)
I
AR
Non-Repetitive Avalanche Energy
mJ
Repetitive Avalanche Current
(Per Leg)
Electrical Specifications
2
A
Current decaying inearly o zero n 1 μsec
Frequency limited by T
J
max. V
A
= 3.0 x V
R
typical
Parameters
225CNQ Units
Conditions
Following any rated
load condition and with
rated V
RRM
applied
A
Parameters
225CNQ Units
Conditions
T
J
= 25 °C
T
J
= 75 °C
V
R
= rated V
R
V
R
= 12 V
V
R
= 5 V
T
J
T
stg
R
thJC
Max. Thermal Resistance Junction
to Case (Per Leg)
R
thJC
Max. Thermal Resistance Junction
to Case (Per Package)
R
thCS
Typical Thermal Resistance, Case
to Heatsink
wt
Approximate Weight
T
Mounting Torque Base
Max. Junction Temperature Range
Max. Storage Temperature Range
-55 o 100
-55 o 100
°C
°C
0.40
°C/W
DC operation
* See Fig. 4
0.20
°C/W
DC operation
0.10
°C/W
Mounting surface smooth and greased
79 (2.80)
40 (35)
58 (50)
17 (15)
58 (50)
86 (75)
g (oz.)
Min.
Max.
Typ.
Min.
Max.
Mounting Torque Center Hole
Terminal Torque
Case Style
TO - 244AB
Modified JEDEC
Thermal-Mechanical Specifications
Parameters
225CNQ Units
Conditions
Kg-cm
(Ibf-in)
(1) Pulse Width < 300μs, Duty Cycle <2%
15