2001 Jul 05
13
BCcomponents
Product specification
Aluminum electrolytic capacitors
High Temperature solid electrolytic SMD
175 TMP
SPECIFIC TESTS AND REQUIREMENTS
General tests and requirements are specified in data handbook BC01, section
“Tests and Requirements”.
Table 6
Test procedures and requirements
TEST
PROCEDURE
(quick reference)
REQUIREMENTS
(1)
NAME OF TEST
REFERENCE
Mounting
IEC 60384-18,
subclause 4.3
shall be performed prior to tests
mentioned below;
reflow soldering;
for maximum temperature load
refer to chapter “Mounting”
T
amb
= 125
°
C;
U
R
= 4 to 25 V with U
R
applied;
U
R
= 40 V with U
C
applied;
10000 hours
C/C:
±
10%
tan
δ ≤
spec. limit
I
L2
≤
spec. limit
Endurance
IEC 60384-4/
EN130300
subclause 4.13
T
amb
= 175
°
C;
U
R
= 4 to 16 V with U
R
applied;
U
R
= 20 to 40 V with U
C
applied;
1000 hours
T
amb
= 175
°
C;
I
R
applied and:
U
R
= 4 to 16 V with U
R
applied;
U
R
= 20 and 40 V with U
C
applied;
2000 hours
C/C:
±
10%
tan
δ ≤
1.2
×
spec. limit
Z
≤
1.2
×
spec. limit
I
L5
≤
spec. limit
Useful life
CECC 30302
subclause 1.8.1
C/C:
±
15%
tan
δ ≤
1.5
×
spec. limit
Z
≤
1.5
×
spec. limit
I
L5
≤
spec. limit
no short or open circuit,
no visible damage
total failure percentage:
<
1%
C/C:
±
10%
Shelf life (storage
at high
temperature)
IEC 60384-4/
EN130300
subclause 4.17
T
amb
= 85
°
C; no voltage applied;
5000 hours
tan
δ ≤
1.2
×
spec. limit
I
L5
≤
1
×
spec. limit
C/C:
±
5%
Charge and
discharge
IEC 60384-4-2
subclause 9.21
10
6
cycles without series resistance:
0.5 s to U
R
;
0.5 s to ground
no short or open circuit,
no visible damage
visual appearance not affected
Solvent
resistance
IEC 60068-2-45,
test XA
IEC 60653
immersion: 5
±
0.5 minutes with or
without ultrasonic at 55
±
5
°
C
solvents: demineralized water and/or
calgonite solution (20 g/l)