ECL OperationDMilitary Version
DC Electrical Characteristics
V
CC
e
V
CCA
e
GND, V
EE
e b
5.2V
Symbol
Parameter
Min
Typ
Max
Units
T
A
Conditions
V
OH
Output HIGH Voltage
Q and Q
b
1100
b
980
b
910
b
1030
b
910
b
820
b
900
b
820
b
670
b
55
§
C
a
25
§
C
a
125
§
C
b
55
§
C to
a
125
§
C
b
55
§
C
a
25
§
C
a
125
§
C
b
55
§
C
a
25
§
C
a
125
§
C
Load
e
100
X
to
b
2V
mV
V
OL
Output LOW Voltage
Q and Q
b
1820
b
1705
b
1620
mV
V
IH
Input HIGH Voltage
b
1190
b
1095
b
975
b
905
b
810
b
690
Guaranteed Input HIGH
Signal (Note 6)
mV
V
IL
Input LOW Voltage
b
1890
b
1850
b
1800
b
1525
b
1485
b
1435
Guaranteed Input LOW
Signal
mV
I
IH
Input HIGH Current
CP Input (Note 1)
MS Input
M
1
and M
2
Input
V
IN
e
V
IHA
400
400
250
a
25
§
C
a
25
§
C
a
25
§
C
a
25
§
C
a
25
§
C
b
55
§
C to
a
125
§
C
b
55
§
C to
a
125
§
C
m
A
I
IL
Input LOW Current
0.5
m
A
V
IN
e
V
ILB
I
EE
Power Supply Current
b
110
b
75
mA
Pins 6, 7, 13 not connected
b
119
mA
V
EE
Operating Supply
Voltage Range
b
5.7
b
5.2
b
4.7
V
V
REF
Reference Voltage
b
1550
b
1150
mV
a
25
§
C
V
RM1
e
V
RM2
e b
5.2V
I
N
10.0
m
A
AC Electrical Characteristics
T
A
e b
55
§
C to
a
125
§
C, V
CC
e
V
CCA
e
GND, V
EE
e b
5.2V
Symbol
Parameter
b
55
§
C
Typ
a
25
§
C
a
125
§
C
Typ
Units
Conditions
Min
Typ
Max
t
PLH
t
PHL
Propagation Delay,
(50% to 50%) CP to Q
1.5
1.3
2.0
3.0
3.0
ns
Output:
R
L
e
50
X
to
b
2.0V
t
PLH
Propagation Delay,
(50% to 50%) MS to Q
3.5
4.0
6.0
5.0
ns
Input:
t
ri
e
t
fi
e
2.0
g
0.1 ns
(20% to 80%)
SeeFigure 1
t
s
Setup Time, M to CP
2.0
4.0
2.0
2.0
ns
t
h
Hold Time, M to CP
b
2.0
0.0
b
2.0
b
2.0
ns
t
TLH
Output Rise Time
(20% to 80%)
1.0
1.0
2.0
1.0
ns
t
THL
Output Fall Time
(80% to 20%)
1.0
1.0
2.0
1.0
ns
f
MAX
Maximum Clock Frequency
AC Coupled Input 350 mV
Peak-to-Peak. f
MAX
is
Guaranteed to be 550 MHz
Min at
b
55
§
C to
a
125
§
C.
700
600
650
600
MHz
Note 1:
Conditions for testing, not shown in the Table, are chosen to guarantee operation under ‘‘worst case’’ conditions.
Note 2:
The specified limits represent the ‘‘worst case’’ value for the parameter. Since these ‘‘worst case’’ values normally occur at the temperature and supply
voltage extremes, additional noise immunity and guard banding can be achieved by decreasing the allowable system operating ranges.
Note 3:
Typical limits are at V
CC
e
5.0V and T
A
e a
25
§
C.
Note 4:
The M
1
and M
2
threshold specifications are normally referenced to the V
CC
potential, as shown in the ECL operation tables. Using V
EE
(GND) as the
reference, as in normal TTL practice, effectively makes the threshold vary directly with V
CC
. Threshold is typically 1.3V below V
CC
(e.g.,
a
3.7V at V
CC
e a
5V). A
signal swing about threshold of
g
0.4V is adequate, which gives the state V
IH
and V
IL
values. The internal 2 k
X
resistors are intended to pull TTL outputs up to the
required V
IH
range, as discussed in the Functional Description and shown in Figure 5.
Note 5:
TTL Output Signal swing is guaranteed at f
MAX
over temperature range.
Note 6:
M
1
or M
2
can be tied to V
CC
for fixed divide-by-ten operation.
4