LM1117I Electrical Characteristics
Typicals and limits appearing in normal type apply for T
J
= 25C. Limits appearing in
Boldface
type apply over the entire junc-
tion temperature range for operation, 40C to 125C.
Symbol
Parameter
Conditions
Min
(Note 5)
Typ
(Note 4)
Max
(Note 5)
Units
V
REF
Reference Voltage
LM1117I-ADJ
I
OUT
= 10mA, V
IN
-V
OUT
= 2V, T
J
= 25C
10mA
≤
I
OUT
≤
800mA, 1.4V
≤
V
IN
-V
OUT
≤
10V
LM1117I-3.3
I
OUT
= 10mA, V
IN
= 5V, T
J
= 25C
0
≤
I
OUT
≤
800mA, 4.75V
≤
V
IN
≤
10V
LM1117I-5.0
I
OUT
= 10mA, V
IN
= 7V, T
J
= 25C
0
≤
I
OUT
≤
800mA, 6.5V
≤
V
IN
≤
12V
LM1117I-ADJ
I
OUT
= 10mA, 1.5V
≤
V
IN
-V
OUT
≤
13.75V
LM1117I-3.3
I
OUT
= 0mA, 4.75V
≤
V
IN
≤
15V
LM1117I-5.0
I
OUT
= 0mA, 6.5V
≤
V
IN
≤
15V
LM1117I-ADJ
V
IN
-V
OUT
= 3V, 10
≤
I
OUT
≤
800mA
LM1117I-3.3
V
IN
= 4.75V, 0
≤
I
OUT
≤
800mA
LM1117I-5.0
V
IN
= 6.5V, 0
≤
I
OUT
≤
800mA
I
OUT
= 100mA
I
OUT
= 500mA
I
OUT
= 800mA
V
IN
-V
OUT
= 5V, T
J
= 25C
LM1117I-ADJ
V
IN
= 15V
LM1117I-3.3
V
IN
≤
15V
LM1117I-5.0
V
IN
≤
15V
T
A
= 25C, 30ms Pulse
f
RIPPLE
=1 20Hz, V
IN
-V
OUT
= 3V V
RIPPLE
= 1V
PP
1.238
1.200
1.250
1.250
1.262
1.290
V
V
V
OUT
Output Voltage
3.267
3.168
3.300
3.300
3.333
3.432
V
V
4.950
4.800
5.000
5.000
5.050
5.200
V
V
V
OUT
Line Regulation
(Note 6)
0.035
0.3
%
1
10
mV
1
15
mV
V
OUT
Load Regulation
(Note 6)
0.2
0.5
%
1
15
mV
1
20
1.30
1.35
1.40
1500
mV
V
V
V
mA
V
IN
-V
OUT
Dropout Voltage
(Note 7)
1.10
1.15
1.20
1200
I
LIMIT
Current Limit
Minimum Load
Current (Note 8)
Quiescent Current
800
1.7
5
mA
5
15
mA
5
15
0.1
mA
%/W
dB
Thermal Regulation
Ripple Regulation
0.01
75
60
Adjust Pin Current
Adjust Pin Current
Change
Temperature Stability
Long Term Stability
RMS Output Noise
Thermal Resistance
Junction-to-Case
60
120
μA
10
≤
I
OUT
≤
800mA,
1.4V
≤
V
IN
-V
OUT
≤
10V
0.2
0.5
0.3
0.003
15.0
10
136
92
40
10
μA
%
%
%
C/W
C/W
C/W
C/W
C/W
T
A
= 125C, 1000Hrs
(% of V
OUT
), 10Hz
≤
f
≤
10kHz
3-Lead SOT-223
3-Lead TO-252
3-Lead SOT-223 (No heat sink)
3-Lead TO-252 (No heat sink)(Note 9)
8-Lead LLP(Note 10)
Thermal Resistance
Junction-to-Ambient
No air flow)
Note 1:
Absolute Maximum Ratings indicate limits beyond which damage to the device may occur. Operating Ratings indicate conditions for which the device is
intended to be functional, but specific performance is not guaranteed. For guaranteed specifications and the test conditions, see the Electrical Characteristics.
L
www.national.com
6