Bel Fuse Inc.
206 Van Vorst Street, Jersey City, NJ 07302
Tel 201-432-0463 Fax 201-432-9542 www.belfuse.com
ISOLATED DC/DC CONVERTERS
48 Vdc Input 1.2-2.5 Vdc/80 A, 3.3 Vdc/70 A, 5 Vdc/48 A, 12 Vdc/20 A Output
Isolated
Output Over Voltage Shutdown
High Efficiency
OCP/SCP
High Power Density
Over Temperature Protection
Low Cost
Remote On/Off
Input Under Voltage Lockout
Output Voltage Trim
Fixed frequency (330 kHz)
Basic Isolation
Input Over Voltage Lockout
Positive/Negative Remote Sense
Remote On/Off Logic (option)
UL60950-1 Recognized (UL/cUL)
Description
The 0RHB-D0T Series are isolated dc/dc converters that operate from a nominal 48 Vdc source. These units
provide up to 200 W of output power from a nominal 48 Vdc input. These units are designed to be highly efficient
and low cost. Features include remote on/off, over current protection and under voltage lockout. These
converters are provided in an industry standard half-brick package.
Part Selection
Output
Voltage
Input
Voltage
Max. Output
Current
Max. Output
Power
Typical
Efficiency
Model Number
Active High
Model Number
Active Low
12.0 V
36 V - 75 V
20 A
240 W
94%
0RHB-D0T120
0RHB-D0T12L
5.0 V
36 V - 75 V
48 A
240 W
92.5%
0RHB-D0T050
0RHB-D0T05L
3.3 V
36 V - 75 V
70 A
231 W
92%
0RHB-D0T033
0RHB-D0T03L
2.5 V
36 V - 75 V
80 A
200 W
91%
0RHB-D0T025
0RHB-D0T02L
1.8 V
36 V - 75 V
80 A
144 W
89%
0RHB-D0TV80
0RHB-D0TV8L
1.5 V
36 V - 75 V
80 A
120 W
87%
0RHB-D0TV50
0RHB-D0TV5L
1.2 V
36 V - 75 V
80 A
96 W
85%
0RHB-D0TV20
0RHB-D0TV2L
Notes
: 1. Add “G” suffix at the end of the model number to indicate Tray Packaging.
2. All part numbers above indicate RoHS 6. Change the second letter "R" to "7" for RoHS 5 part numbers.
Absolute Maximum Ratings
Parameter
Min
Typ
Max
Notes
Input Voltage (continuous)
-0.3 V
-
80 V
Remote On/Off
-0.3 V
-
18 V
I/O Isolation Voltage
-
2000 V
Ambient Temperature
-40
°C
-
85
°C
Storage Temperature
-55
°C
-
125
°C
0RHB-D0T Series
RoHS Compliant
Rev.A