www.ti.com
TS5A2066
DUAL-CHANNEL 10-
SPST ANALOG SWITCH
SCDS184A–JANUARY 2005–REVISED SEPTEMBER 2005
PIN DESCRIPTION
NO.
1
2
3
4
5
6
7
8
NAME
NO1
COM1
IN2
GND
NO2
COM2
IN1
V
+
DESCRIPTION
Normally open
Common
Digital control to connect COM to NO
Digital ground
Normally open
Common
Digital control to connect COM to NO
Power supply
PARAMETER DESCRIPTION
SYMBOL
V
COM
V
NO
r
on
r
on
r
on(flat)
I
NO(OFF)
DESCRIPTION
Voltage at COM
Voltage at NO
Resistance between COM and NO ports when the channel is ON
Difference of r
on
between channels in a specific device
Difference between the maximum and minimum value of r
on
in a channel over the specified range of conditions
Leakage current measured at the NO port, with the corresponding channel (NO to COM) in the OFF state
Leakage current measured at the NO port, with the corresponding channel (NO to COM) in the ON state and the output
(COM) open
Leakage current measured at the COM port, with the corresponding channel (COM to NO) in the OFF state
Leakage current measured at the COM port, with the corresponding channel (COM to NO) in the ON state and the output
(NO) open
Minimum input voltage for logic high for the control input (IN)
Maximum input voltage for logic low for the control input (IN)
Voltage at the control input (IN)
Leakage current measured at the control input (IN)
Turn-on time for the switch. This parameter is measured under the specified range of conditions and by the propagation
delay between the digital control (IN) signal and analog output (COM or NO) signal when the switch is turning ON.
Turn-off time for the switch. This parameter is measured under the specified range of conditions and by the propagation
delay between the digital control (IN) signal and analog output (COM or NO) signal when the switch is turning OFF.
Charge injection is a measurement of unwanted signal coupling from the control (IN) input to the analog (NO or COM)
output. This is measured in coulomb (C) and measured by the total charge induced due to switching of the control
input.Charge injection, Q
C
= C
L
×
V
COM
, C
L
is the load capacitance and
V
COM
is the change in analog output voltage.
Capacitance at the NO port when the corresponding channel (NO to COM) is OFF
Capacitance at the NO port when the corresponding channel (NO to COM) is ON
Capacitance at the COM port when the corresponding channel (COM to NO) is OFF
Capacitance at the COM port when the corresponding channel (COM to NO) is ON
Capacitance of IN
OFF isolation of the switch is a measurement of OFF-state switch impedance. This is measured in dB in a specific
frequency, with the corresponding channel (NO to COM) in the OFF state.
Crosstalk is a measurement of unwanted signal coupling from an ON channel to an adjacent ON channel (NC1 to NC2).
This is measured in a specific frequency and in dB.
Bandwidth of the switch. This is the frequency in which the gain of an ON channel is -3 dB below the DC gain.
Total harmonic distortion is defined as the ratio of the root mean square (RMS) value of the second, third, and higher
harmonics to the magnitude of fundamental harmonic.
Static power-supply current with the control (IN) pin at V
+
or GND
I
NO(ON)
I
COM(OFF)
I
COM(ON)
V
IH
V
IL
V
I
I
IH
, I
IL
t
ON
t
OFF
Q
C
C
NO(OFF)
C
NO(ON)
C
COM(OFF)
C
COM(ON)
C
I
O
ISO
X
TALK
BW
THD
I
+
16