GaAs Transfer Switch,
DC-3.0 GHz
SW-283-PIN
M/A-COM Inc. and its affiliates reserve the right to make changes to the
product(s) or information contained herein without notice. M/A-COM makes
no warranty, representation or guarantee regarding the suitability of its
products for any particular purpose, nor does M/A-COM assume any liability
whatsoever arising out of the use or application of any product(s) or
information.
North America
Tel: 800.366.2266 / Fax: 978.366.2266
Europe
Tel: 44.1908.574.200 / Fax: 44.1908.574.300
Asia/Pacific
Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Visit www.macom.com
for additional data sheets and product information.
V4
2
RoHS
Compliant
Electrical Specifications: T
A
= 25°C, Z
0
= 50
1,2
Parameter
Test Conditions
Frequency
Units
Min
Typ
Max
Insertion Loss
—
DC - 3 GHz
DC - 2 GHz
DC - 1 GHz
DC - 0.5 GHz
dB
dB
dB
dB
—
—
—
—
—
—
—
—
2.1
1.8
1.3
1.0
VSWR
—
DC - 3 GHz
DC - 2 GHz
DC - 1 GHz
DC - 0.5 GHz
Ratio
Ratio
Ratio
Ratio
—
—
—
—
—
—
—
—
1.9:1
1.7:1
1.3:1
1.25:1
Isolation
—
DC - 3 GHz
DC - 2 GHz
DC - 1 GHz
DC - 0.5 GHz
dB
dB
dB
dB
20
25
40
45
—
—
—
—
—
—
—
—
Trise, Tfall
Ton, Toff
Transients
10/90% or 90/10% RF
50% CTL to 90/10% RF
In-Band
—
—
—
nS
nS
mV
—
—
—
2
4
30
—
—
—
1 dB Compression
Control Voltage 0/-5 VDC
Control Voltage 0/-8 VDC
0.5 - 3 GHz
0.05 GHz
0.5 - 3 GHz
0.05 GHz
dBm
dBm
dBm
dBm
—
—
—
—
+27
+21
+33
+26
—
—
—
—
IP
2
For two-tone Input power
up to +13 dBm
0.5 - 3 GHz
0.05 GHz
dBm
dBm
—
—
+68
+62
—
—
IP
3
For two-tone Input power
up to +13 dBm
0.5 - 3 GHz
0.05 GHz
dBm
dBm
—
—
+50
+45
—
—
Control Voltages
V
IN
Low: 0 to –0.2V
V
IN
High: -5V @ 10 μA Typ
to –8V
—
—
—
—
—
—
—
—
5 μA
200 μA
1. All specifications apply with 50 ohm impedance connected to all RF ports with 0 and –5 VDC control voltages.
2. Faster switching speed can be achieved with enhanced driver waveform.
Absolute Maximum Ratings
3,4
Parameter
Absolute Maximum
Input Power
0.05 GHz
0.5 - 3.0 GHz
+27 dBm
+34 dBm
Control Voltage
-8.5 V < Vc < +5 V
Operating Temperature
-55°C to +125°C
Storage Temperature
-65°C to +150°C
3.
Exceeding any one or combination of these limits may
cause permanent damage to this device.
M/A-COM does not recommend sustained operation near
these survivability limits.
4.