SSD1852
Rev 1.0
01/2003
SOLOMON
19
8
COMMAND TABLE
Table 3 - Command Table
(
D/C
= 0,
R/
W
(
WR
)
= 0,
E(
RD
)
= 1)
Bit Pattern
0000 C
3
C
2
C
1
C
0
Command
Set Lower Column
Address
Set Upper Column
Address
Set Internal Regulator
Resistor Ratio
Description
Set the lower nibble of the column address pointer for
RAM access. The pointer is reset to 0 after reset.
Set the upper nibble of the column address pointer for
RAM access. The pointer is reset to 0 after reset.
The internal regulator gain (1+R
2
/R
1
) Vout increases as
R
2
R
1
R
0
is increased from 000b to 111b. The factor,
1+R
2
/R
1
, is given by:
R
2
R
1
R
0
= 000: 3.45 (POR)
R
2
R
1
R
0
= 001: 4.50
R
2
R
1
R
0
= 010: 5.55
R
2
R
1
R
0
= 011: 6.60
R
2
R
1
R
0
= 100: 7.65
R
2
R
1
R
0
= 101: 8.70
R
2
R
1
R
0
= 110: 9.75
R
2
R
1
R
0
= 111: 10.8
VC=0: turn OFF the internal voltage booster (POR)
VC=1: turn ON the internal voltage booster
VR=0: turn OFF the internal regulator (POR)
VR=1: turn ON the internal regulator
VF=0: turn OFF the output op-amp buffer (POR)
VF=1: turn ON the output op-amp buffer
The second command specifies the row address pointer
(0-127) of the RAM data to be displayed in COM0. This
command has no effect on ICONS. The pointer is set to 0
after reset.
The second command specifies the mapping of first
display line (COM0) to one of ROW0~127. This command
has no effect on ICONS. COM0 is mapped to ROW0 after
reset.
The second command specifies the number of lines,
excluding ICONS, to be displayed. With Icon is disabled
(POR), duties 1/16~1/128 could be selected. With Icon
enabled, the available duty ratios are 1/ 17~ 1/129.
D
7
– D
0
Mux(icon disable) Mux(icon enable)
0000000 invalid invalid
…
00001111 invalid invalid
00010000 16 17
00010001 17 18
…
10000000 128 129
10000001 invalid invalid
10000010 invalid invalid
…
11111111 invalid invalid
0001 0C
6
C
5
C
4
0010 0R
2
R
1
R
0
0010 1VC VR VF
Set Power Control
Register
0100 00XX
XL
6
L
5
L
4
L
3
L
2
L
1
L
0
Set Display Start Line
0100 01XX
XC
6
C
5
C
4
C
3
C
2
C
1
C
0
Set Display Offset
0100 10XX
D
7
D
6
D
5
D
4
D
3
D
2
D
1
D
0
Set Multiplex Ratio
(Partial Display)