9.13 Set PWM and FRC
This command is used to select the number of frames used in frame rate control, and the
number of levels in the pulse width modulation.
9.14 Set Segment Re-map
This command changes the mapping between the display data column address and
segment driver. It allows flexibility in layout during LCD module assembly. Refer to Figure 7.
9.15 Set Icon Enable
This command enable/disable the Icon display. When Icon display is enabled and page
address is set to Page 16. This is only one way to set the page address to 16. Therefore, when
writing data for the icon, ICONS control register ON instruction would be used to set the page
address to 16.
9.16 Set Entire Display On/Off
This command forces the entire display, including the icon row, to be “ON” regardless of
the contents of the display data RAM. This command has priority over normal/invert display. To
execute this command, Set Display On command must be sent in advance.
9.17 Set Normal/Inverse Display
This command sets the display to be either normal/inverse. In normal display, a RAM
data of 1 indicates an “ON” pixel. While in invert display, a RAM data of 0 indicates an “ON”
pixel. The icon line is not affected by this command.
9.18 Set Power Save Mode
This command is used to force the chip to enter Sleep Mode.
9.19 Start Internal Oscillator
After POR, the internal oscillator is OFF. It should be turned ON by sending this
command to the chip.
9.20 Set Display On/Off
This command turns the display on/off, by the value of the LSB.
9.21 Set Page Address
This command positions the page address to 0 to 15 possible positions in GDDRAM.
Refer to figure 7.
Set Page Address command cannot be used to set the page address to “16”. Use ICON
control register ON/OFF command to set the page address to “16”.
9.22 Set COM Output Scan Direction
This command sets the scan direction of the COM output allowing layout flexibility in LCD
module assembly.
9.23 Set Modify-Read
This command stops the automatic increment of the column address after read display
data. The column address is still automatic increment due to write display data.
相關(guān)PDF資料
PDF描述
SSD1852TR1 LCD Segment / Common Driver With Controller CMOS
SSD1852Z LCD Segment / Common Driver With Controller CMOS
SSD1854U LCD Segment / Common Driver with Controller CMOS
SSD1854Z LCD Segment / Common Driver with Controller CMOS
SSD1854 LCD Segment / Common Driver with Controller CMOS
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
SSD1852TR1 制造商:未知廠家 制造商全稱:未知廠家 功能描述:LCD Segment / Common Driver With Controller CMOS
SSD1852Z 制造商:未知廠家 制造商全稱:未知廠家 功能描述:LCD Segment / Common Driver With Controller CMOS
SSD1854 制造商:未知廠家 制造商全稱:未知廠家 功能描述:LCD Segment / Common Driver with Controller CMOS
SSD1854U 制造商:未知廠家 制造商全稱:未知廠家 功能描述:LCD Segment / Common Driver with Controller CMOS
SSD1854Z 制造商:未知廠家 制造商全稱:未知廠家 功能描述:LCD Segment / Common Driver with Controller CMOS