SN74ABT7819A
512
×
18
×
2
CLOCKED BIDIRECTIONAL FIRST-IN, FIRST-OUT MEMORY
SCBS756
–
MAY 2002
15
POST OFFICE BOX 655303
DALLAS, TEXAS 75265
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage range, V
CC
Input voltage range, V
I
(see Note 1)
Voltage range applied to any output in the high state or power-off state, V
O
Current into any output in the low state, I
O
Input clamp current, I
IK
(V
I
< 0)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Output clamp current, I
OK
(V
O
< 0)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Package thermal impedance,
θ
JA
(see Note 2): PH package
PN package
Storage temperature range, T
stg
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Stresses beyond those listed under
“
absolute maximum ratings
”
may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under
“
recommended operating conditions
”
is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES:
1. The input and output negative-voltage ratings may be exceeded if the input and output clamp-current ratings are observed.
2. The package thermal impedance is calculated in accordance with JESD 51
–
7.
–
0.5 V to 7 V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
–
0.5 V to V
CC
+ 0.5 V
–
0.5 V to 5.5 V
. . . . . . . . . . . . . .
48 mA
–
18 mA
–
50 mA
72
°
C/W
62
°
C/W
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
–
65
°
C to 150
°
C
recommended operating conditions
MIN
NOM
MAX
UNIT
VCC
VIH
VIL
VI
IOH
IOL
t/
v
TA
Supply voltage
4.5
5
5.5
V
High-level input voltage
2
V
Low-level input voltage
0.8
V
Input voltage
0
VCC
–
12
V
High-level output current
mA
Low-level output current
24
mA
Input transition rise or fall rate
5
ns/V
°
C
Operating free-air temperature
0
70
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNIT
VIK
VCC = 4.5 V,
VCC = 4.5 V,
VCC = 5 V,
VCC = 4.5 V,
VCC = 4.5 V,
VCC = 5.5 V,
VCC = 5.5 V,
VCC = 5.5 V,
VCC = 5.5 V,
II =
–
18 mA
IOH =
–
3 mA
IOH =
–
3 mA
IOH =
–
12 mA
IOL = 24 mA
VI = VCC or GND
VO = 2.7 V
VO = 0.5 V
VO = 2.5 V
Outputs high
–
1.2
V
2.5
VOH
3
V
2
VOL
II
IOZH
§
IOZL
§
IO
0.5
V
μ
A
μ
A
μ
A
mA
±
1
50
–
50
–
40
–
100
–
180
VCC = 5.5 V, IO = 0,
VI= VCCor GND
VI = VCC or GND
5 5 V I
15
ICC
Outputs low
95
mA
Outputs disabled
15
Ci
Cio
Control inputs
VI = 2.5 V or 0.5 V
VO = 2.5 V or 0.5 V
12
pF
A or B ports
14
pF
All typical values are at VCC = 5 V, TA = 25
°
C.
§
The parameters IOZH and IOZL include the input leakage current.
Not more than one output should be tested at a time, and the duration of the test should not exceed one second.