SN54ALS652, SN54ALS653, SN54AS651, SN54AS652
SN74ALS651A, SN74ALS652A, SN74ALS653, SN74ALS654, SN74AS651, SN74AS652
OCTAL BUS TRANSCEIVERS AND REGISTERS WITH 3-STATE OUTPUTS
SDAS066F – DECEMBER 1983 – REVISED OCTOBER 1996
12
POST OFFICE BOX 655303
DALLAS, TEXAS 75265
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage, V
CC
Input voltage, V
I
: All inputs and A I/O ports
B I/O ports
Operating free-air temperature range, T
A
: SN54ALS653
7 V
7 V
5.5 V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SN74ALS653, SN74ALS654
Storage temperature range, T
stg
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
–55
°
C to 125
°
C
0
°
C to 70
°
C
–65
°
C to 150
°
C
. . . . . . . . . . . . . . . . . . . .
recommended operating conditions
SN54ALS653
SN74ALS653
UNIT
MIN
NOM
MAX
MIN
NOM
MAX
VCC
VIH
VIL
VOH
IOH
IOL
fclock
Supply voltage
4.5
5
5.5
4.5
5
5.5
V
High-level input voltage
2
2
V
Low-level input voltage
0.7
0.8
V
High-level output voltage
A ports
5.5
5.5
V
High-level output current
B ports
–12
–15
mA
Low-level output current
12
24
mA
Clock frequency
0
25
0
35
MHz
tw
Pulse duration
CLKBA or CLKAB high
20
14.5
ns
CLKBA or CLKAB low
20
14.5
tsu
th
TA
Setup time before CLKAB
↑
or CLKBA
↑
Hold time after CLKAB
↑
or CLKBA
↑
Operating free-air temperature
A or B
15
10
ns
A or B
5
0
ns
°
C
–55
125
0
70
recommended operating conditions
SN74ALS654
MIN
NOM
UNIT
MAX
VCC
VIH
VIL
VOH
IOH
IOL
fclock
Supply voltage
4.5
5
5.5
V
High-level input voltage
2
V
Low-level input voltage
0.8
V
High-level output voltage
A ports
5.5
V
High-level output current
B ports
–15
mA
Low-level output current
24
mA
Clock frequency
0
35
MHz
tw
Pulse duration
CLKBA or CLKAB high
14.5
ns
CLKBA or CLKAB low
14.5
tsu
th
TA
Setup time before CLKAB
↑
or CLKBA
↑
Hold time after CLKAB
↑
or CLKBA
↑
Operating free-air temperature
A or B
10
ns
A or B
0
ns
°
C
0
70