SN54ABT16260, SN74ABTH16260
12-BIT TO 24-BIT MULTIPLEXED D-TYPE LATCHES
WITH 3-STATE OUTPUTS
SCBS204C – JUNE 1992 – REVISED MAY 1997
4
POST OFFICE BOX 655303
DALLAS, TEXAS 75265
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage range, V
CC
Input voltage range, V
I
(see Note 1)
Voltage range applied to any output in the high or power-off state, V
O
Current into any output in the low state, I
O
: SN54ABT16260
–0.5 V to 7 V
–0.5 V to 7 V
–0.5 V to 5.5 V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SN74ABTH16260
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Output clamp current, I
OK
(V
O
< 0)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Package thermal impedance,
θ
JA
(see Note 2): DL package
Storage temperature range, T
stg
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES:
1. The input and output negative-voltage ratings may be exceeded if the input and output clamp-current ratings are observed.
2. The package thermal impedance is calculated in accordance with EIA/JEDEC Std JESD51.
96 mA
128 mA
–18 mA
–50 mA
74
°
C/W
Input clamp current, I
IK
(V
I
< 0)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
–65
°
C to 150
°
C
recommended operating conditions (see Note 3)
SN54ABT16260
MIN
SN74ABTH16260
MIN
UNIT
MAX
MAX
VCC
VIH
VIL
VI
IOH
IOL
t/
v
t/
VCC
TA
NOTE 3: Unused control inputs must be held high or low to prevent them from floating.
Supply voltage
4.5
5.5
4.5
5.5
V
High-level input voltage
2
2
V
Low-level input voltage
0.8
0.8
V
Input voltage
0
VCC
–24
0
VCC
–32
V
High-level output current
mA
Low-level output current
48
64
mA
Input transition rise or fall rate
Outputs enabled
10
10
ns/V
μ
s/V
°
C
Power-up ramp rate
200
200
Operating free-air temperature
–55
125
–40
85