Rev. 2.0, 09/02, page 223 of 732
11.3.5
Timer Status Register (TSR)
The TSR registers are 8-bit readable/writable registers that indicate the status of each channel. The
MTU has five TSR registers, one for each channel.
Bit
Bit Name
Initial value R/W
Description
7
TCFD
1
R
Count Direction Flag
Status flag that shows the direction in which TCNT
counts in channels 1, 2, 3, and 4.
In channel 0, bit 7 is reserved. It is always read as 1 and
should be written with 1.
0: TCNT counts down
1: TCNT counts up
6
—
1
R
Reserved
This bit is always read as 1 and should be written with 1.
5
TCFU
0
R/(W)
*
Underflow Flag
Status flag that indicates that TCNT underflow has
occurred when channels 1 and 2 are set to phase
counting mode. Only 0 can be written, for flag clearing.
In channels 0, 3, and 4, bit 5 is reserved. It is always
read as 0 and should be written with 0.
[Setting condition]
When the TCNT value underflows (changes from
H'0000 to H'FFFF)
[Clearing condition]
When 0 is written to TCFU after reading TCFU = 1
Overflow Flag
Status flag that indicates that TCNT overflow has
occurred. Only 0 can be written, for flag clearing.
[Setting condition]
4
TCFV
0
R/(W)
*
When the TCNT value overflows (changes from
H'FFFF to H'0000 )
In channel 4, when the TCNT_4 value underflows
(changes from H'0001 to H'0000) in complementary
PWM mode, this flag is also set.
[Clearing condition]
When 0 is written to TCFV after reading TCFV = 1
In cannel 4, when DTC is activated by TCIV interrupt
and the DISEL bit of DTMR in DTC is 0, this flag is
also cleared.