October 29, 2004 S29WSxxxN_00_F0
87
Pre l i m i n a r y
Table 12.2. Sector Protection Commands
Command Sequence
(Notes)
Cy
cl
es
First
Second
Third
Fourth
Fifth
Sixth
Seventh
Addr
Data
Addr
Data
Addr
Data
Addr
Data Addr Data Addr Data Addr Data
Lock
Register
Bits
3
555
AA
2AA
55
555
40
2
XX
A0
77
data
1
77
data
2
XX
90
XX
00
Password
Protection
3
555
AA
2AA
55
555
60
2
XX
A0
00
PWD[0-3]
4 0...00 PWD0 0...01
PWD1
0...02
PWD2 0...03 PWD3
Unlock
7
00
25
00
03
00
PWD0
01
PWD1
02
PWD2
03
PWD3
00
29
2
XX
90
XX
00
Non-Volatile
Sector
Protection (PPB)
3
555
AA
2AA
55
[BA]555
C0
2
XX
A0
SA
00
2
XX
80
00
30
PPB Status Read
1
SA
RD(0)
2
XX
90
XX
00
Global
Volatile Sector
Protection
Freeze
(PPB Lock)
3
555
AA
2AA
55
[BA]555
50
PPB Lock Bit Set
2
XX
A0
XX
00
PPB Lock Bit Status Read
1
BA
RD(0)
2
XX
90
XX
00
Volatile Sector
Protection
(DYB)
3
555
AA
2AA
55
[BA]555
E0
DYB Set
2
XX
A0
SA
00
DYB Clear
2
XX
A0
SA
01
DYB Status Read
1
SA
RD(0)
2
XX
90
XX
00
Legend:
X = Don’t care.
RA = Address of the memory location to be read.
PD(0) = SecSi Sector Lock Bit. PD(0), or bit[0].
PD(1) = Persistent Protection Mode Lock Bit. PD(1), or bit[1], must
be set to ‘0’ for protection while PD(2), bit[2] must be left as ‘1’.
PD(2) = Password Protection Mode Lock Bit. PD(2), or bit[2], must
be set to ‘0’ for protection while PD(1), bit[1] must be left as ‘1’.
PD(3) = Protection Mode OTP Bit. PD(3) or bit[3].
SA = Sector Address. WS256N = A23–A14; WS128N = A22–A14;
WS064N = A21–A14.
BA = Bank Address. WS256N = A23–A20; WS128N = A22–A20;
WS064N = A21–A18.
PWD3–PWD0 = Password Data. PD3–PD0 present four 16 bit
combinations that represent the 64-bit Password
PWA = Password Address. Address bits A1 and A0 are used to select
each 16-bit portion of the 64-bit entity.
PWD = Password Data.
RD(0), RD(1), RD(2) = DQ0, DQ1, or DQ2 protection indicator bit. If
protected, DQ0, DQ1, or DQ2 = 0. If unprotected, DQ0, DQ1,
DQ2 = 1.
Notes:
1. All values are in hexadecimal.
2. Shaded cells indicate read cycles.
3. Address and data bits not specified in table, legend, or notes are
don’t cares (each hex digit implies 4 bits of data).
4. Writing incorrect address and data values or writing them in the
improper sequence may place the device in an unknown state.
The system must write the reset command to return the device
to reading array data.
5. Entry commands are required to enter a specific mode to enable
instructions only available within that mode.
6. If both the Persistent Protection Mode Locking Bit and the
Password Protection Mode Locking Bit are set at the same time,
the command operation will abort and return the device to the
default Persistent Sector Protection Mode during 2nd bus cycle.
Note that on all future devices, addresses will equal 00h, but are
currently 77h for WS256N, WS128N, and WS064N. See Tables
8.1 and
8.2 for explanation of lock bits.
7. Exit command must be issued to reset the device into read
mode; device may otherwise be placed in an unknown state.
8. Entire two bus-cycle sequence must be entered for each portion
of the password.
9. Full address range is required for reading password.
11. “All PPB Erase” command will pre-program all PPBs before
erasure to prevent over-erasure.