Absolute Maximum Ratings (Note 1)
If Military/Aerospace specified devices are required,
please contact the National Semiconductor Sales Office/
Distributors for availability and specifications.
Above which the useful life may be impaired
Storage Temperature (T
STG)
65C to +150C
Maximum Junction Temperature (T
J)
Ceramic
+175C
V
EE Pin Potential to Ground Pin
7.0V to +0.5V
Input Voltage (DC)
V
EE to +0.5V
Output Current (DC Output HIGH)
50 mA
ESD (Note 2)
≥2000V
Recommended Operating
Conditions
Case Temperature (T
C)
Military
55C to +125C
Supply Voltage (V
EE)
5.7V to 4.2V
Note 1: Absolute maximum ratings are those values beyond which the de-
vice may be damaged or have its useful life impaired. Functional operation
under these conditions is not implied.
Note 2: ESD testing conforms to MIL-STD-883, Method 3015.
Military Version
DC Electrical Characteristics
V
EE = 4.2V to 5.7V, VCC = VCCA = GND, TC = 55C to +125C
Symbol
Parameter
Min
Max
Units
T
C
Conditions
Notes
V
OH
Output HIGH Voltage
1025
870
mV
0C to +125C
(Notes 3, 4,
5)
1085
870
mV
55C
V
IN = VIH (Max)
Loading with
V
OL
Output LOW Voltage
1830 1620
mV
0C to +125C
or V
IL(Min)
50
to 2.0V
1830 1555
mV
55C
V
OHC
Output HIGH Voltage
1035
mV
0C to +125C
(Notes 3, 4,
5)
1085
mV
55C
V
IN = VIH (Min)
Loading with
V
OLC
Output LOW Voltage
1610
mV
0C to +125C
or V
IL(Max)
50
to 2.0V
1555
mV
55C
V
IH
Input HIGH Voltage
1165
870
mV
55C to +125C
Guaranteed HIGH Signal
(Notes 3, 4,
5, 6)
for All Inputs
V
IL
Input LOW Current
1830 1475
mV
55C to +125C
Guaranteed LOW Signal
(Notes 3, 4,
5, 6)
for All Inputs
I
IL
Input LOW Current
0.50
A
55C to +125C
V
EE = 4.2V
(Notes 3, 4,
5, 6)
V
IN = VIL (Min)
I
IH
Input High Current
240
A
0C to +125C
V
EE = 5.7V
(Notes 3, 4,
5)
340
A
55C
V
IN = VIH (Max)
I
EE
Power Supply Current
Inputs Open
(Notes 3, 4,
5)
168
55
mA
55C to +125C
V
EE = 4.2V to 4.8V
178
55
mA
V
EE = 4.2V to 5.7V
Note 3: F100K 300 Series cold temperature testing is performed by temperature soaking (to guarantee junction temperature equals 55C), then testing immediately
without allowing for the junction temperature to stabilize due to heat dissipation after power-up. This provides “cold start” specifications which can be considered a
worst case condition at cold temperatures.
Note 4: Screen tested 100% on each device at 55C, +25C and +125C, Subgroups 1, 2, 3, 7, and 8.
Note 5: Sample tested (Method 5005, Table I) on each manufactured lot at 55C, +25C, and +125C, Subgroups A1, 2, 3, 7, and 8.
Note 6: Guaranteed by applying specified input condition and testing VOH/VOL.
AC Electrical Characteristics
V
EE = 4.2V to 5.7V, VCC = VCCA = GND
Symbol
Parameter
T
C = 55C
T
C = +25C
T
C = +125C
Units
Conditions
Notes
Min
Max
Min
Max
Min
Max
f
max
Max Clock Frequency
400
300
MHz
Figures 2, 3
4
t
PLH
Propagation Delay
0.50
2.50
0.50
2.30
0.50
2.80
ns
(Notes 7, 8,
9, 11)
t
PHL
CP to Output
Figures 1, 3
t
TLH
Transition Time
0.30
1.30
0.30
1.30
0.30
1.30
ns
t
THL
20% to 80%,80% to 20%
www.national.com
4