Preferred 100 kW Transient Voltage
Suppressor for AIRCRAFT POWER
BUS PROTECTION
WWW
.Microse
m
i
.CO
M
S C O T TS DALE DIVISION
RT100KP33A thru RT100KP400CA, e3
RT100KP33
A
–
400CA,
e3
ELECTRICAL CHARACTERISTICS at 25C
Rated
Stand-off
Voltage
VWM
Breakdown Voltage
V(BR) Volts
@ I(BR)
V(BR)
I(BR)
Maximum
Clamping
@ IPP (2)
VC
Maximum
Reverse
Leakage
@ VWM
ID
Maximum
Peak Pulse
Current (3)
@6.4/69 s
IPP
Maximum
V(BR)
temperature
Coefficient
α
V(BR)
Part
Number
(1) (4)
VOLTS
mA
VOLTS
μAmps
Amps
mV/
oC
RT100KP33A
RT100KP36A
33
36
36.7-40.6
40.0-44.2
50
58.6
61.8
5000
1825 *
1672 *
38
41
RT100KP40A
RT100KP43A
40
43
44.4-49.1
47.8-52.8
20
10
68.6
71.0
1500
500
1518 *
1432 *
46
50
RT100KP45A
RT100KP48A
45
48
50.0-55.3
53.3-58.9
5
73.0
77.7
150
1365 *
1285 *
52
56
RT100KP51A
RT100KP54A
51
54
56.7-62.7
60.0-66.3
5
82.8
87.5
50
25
1205 *
1139 *
60
63
RT100KP58A
RT100KP60A
58
60
64.4-71.2
66.7-73.7
5
94.0
97.3
15
1066 *
1012 *
68
71
RT100KP64A
RT100KP70A
64
70
71.1-78.6
77.8-86.0
5
104
114
10
959 *
879
76
83
RT100KP75A
RT100KP78A
75
78
83.3-92.1
86.7-95.8
5
122
126
10
819
793
89
93
RT100KP85A
RT100KP90A
85
90
94.4-104
100-111
5
137
146
10
726
686
102
109
RT100KP100A
RT100KP110A
100
110
111-123
122-135
5
162
178
10
619
559
121
133
RT100KP120A
RT100KP130A
120
130
133-147
144-159
5
193
209
10
519
473
145
157
RT100KP150A
RT100KP160A
150
160
167-185
178-197
5
243
259
10
413
386
183
195
RT100KP170A
RT100KP180A
170
180
189-209
200-221
5
275
291
10
366
346
207
219
RT100KP200A
RT100KP220A
200
220
222-245
245-271
5
322
356
10
313
280
243
269
RT100KP250A
RT100KP260A
RT100KP280A
RT100KP300A
250
260
280
300
278-308
289-320
311-345
333-369
5
403
419
451
483
10
246
236
220
206
306
318
344
368
RT100KP350A
RT100KP400A
350
400
389-431
444-492
5
564
644
10
176
153
430
490
1. For bidirectional construction, indicate a CA suffix (instead of A) after the part number
2. Clamping voltage does not include any variable parasitic lead inductance effects observed during the 6.4 s rise time due to lead length.
3. The Maximum Peak Pulse Current (IPP) shown represents the performance capabilities by design.
* Surge test screening is only performed up to 900 Amps (test equipment limitations).
4. Part numbers in bold italics are preferred devices.
Microsemi
Scottsdale Division
Page 2
Copyright
2007
10-03-2007 Rev B
8700 E. Thomas Rd. PO Box 1390, Scottsdale, AZ 85252 USA, (480) 941-6300, Fax: (480) 947-1503