Terms and Definitions
Fault-Triggered 
Preliminary Information 
Summit Microelectronics, Inc 
2086 2.1  12/13/2005 
31 
This term refers to either a power-off or force-shutdown operation. When a UV, OV, or 
sequence termination condition trigger a power-off or force-shutdown a fault triggered power-
off or force-shutdown is said to occur. This sets the restart delay at 2.4s, and can limit the 
number of allowable retries. This term has no correlation to the FAULT pin. 
This term refers to either a power-off or force-shutdown operation. When either the FS# or 
PWR_ON pin is asserted or an I2C command is issued a Command-Triggered power-off or 
force-shutdown is said to occur. This sets the restart delay at 12.5ms, and will not limit the 
number of allowable retries. 
ADOC (Active DC Output Control) is a proprietary secondary closed loop compensation 
control, used to maintain output voltages to ±0.2%. 
Power-off sequencing refers to cascaded power-off sequencing unless explicitly noted.  
Cascaded power-off sequencing refers to a feedback based supply termination in which each 
channel in the previous sequence position is monitored, and the monitored voltage must fall 
below a programmable OFF threshold before the next sequence position is allowed to turn 
off. Channels in the same sequence position are not capable of Cascaded power-off 
sequencing. 
Power-off sequencing refers to cascaded power-off sequencing unless explicitly noted.  
Cascaded power-off sequencing refers to a feedback based supply termination in which each 
channel in the previous sequence position is monitored, and the monitored voltage must fall 
below a programmable OFF threshold before the next sequence position is allowed to turn 
off. Channels in the same sequence position are not capable of Cascaded power-off 
sequencing. 
When all supplies are immediately disabled without regard to sequence position. 
When more than one SMM766 or SMM766 derivatives are connected creating a seamless 
multi-channel network. 
Programmed Under Voltage threshold for monitored channels and supplies 
Programmed Over Voltage threshold for monitored channels and supplies 
Undervoltage Lockout. Prevents voltage at VDD or 12VIN pin from powering the SMM766 
until proper operating voltages have been reached. 
The ability to change the nominal output voltage by use of trim pin. 
Analog to Digital Converter. Converts analog voltage to digital voltage. SMM766 represents 
all measured voltages by 10-bit digital reading. 
The number of times the SMM766 will restart after a Fault-Triggered power-off or force-
shutdown. 
When the SMM766 begins power on sequencing, includes initial power-on sequence. 
Delay from restart timer expiration to PUP
Y
 pin active 
Programmable delay from VM
X
 off to PUP
Y
 inactive 
When a supply fails to reach its programmed UV, or OFF, threshold before expiration of 
internal timer. 
When any quantity including temperature, and voltage is converted to a digital value by the 
ADC and compared against a user programmable setting. 
Graphical user interface. Program that reads from and writes to non-volatile registers on the 
SMM766 and displays results in accordance to register function.  
Command-Triggered 
ADOC 
Power-off 
Power-on 
Force-shutdown 
Sequence-Link 
UV 
OV 
UVLO 
Margin 
ADC  
Retries 
Restart 
Power-on delay 
Power-off delay 
Sequence 
Termination 
Monitoring 
GUI