2.3.3 Packet Header
The packet header contains the first 6 bytes of the packet when
1-byte logical addressing is used. When 8-byte physical
addressing is used, the source and destination addresses each
contain 8 bytes. In this case, the header can consist of a
maximum of 20 bytes. Unused fields marked RSVD are for future
expansion and are transmitted as bit 0. Table 2-2 describes the
PLT packet header fields in detail.
Table 2-2. Powerline Transceiver (PLT) Packet Header
2.3.4 Payload
The packet payload has a length of 0 to 31 bytes. Payload
content is user defined and can be read or written through I2C.
2.3.5 Packet CRC
The last byte of the packet is an 8-bit CRC value used to check
packet data integrity. This CRC calculation includes the header
and payload portions of the packet and is in addition to the
powerline packet header CRC.
2.3.6 Sequence Numbering
The sequence number is increased for every new unique packet
transmitted. If in acknowledged mode and an acknowledgment
is not received for a given packet, that packet will be re-trans-
mitted (if TX_Retry > 0) with the same sequence number. If in
unacknowledged mode, the packet will be transmitted (TX_Retry
+ 1) times with the same sequence number.
If the receiver receives consecutive packets from the same
source address with the same sequence number and packet
CRC, it does not notify the host of the reception of the duplicate
packet. If in acknowledged mode, it still sends an acknowl-
edgment so that the transmitter knows that the packet was
received.
2.3.7 Addressing
The CY8CLED16P01 has three modes of addressing:
Logical addressing: Every CY8CLED16P01 node can have
either a 8-bit logical address or a 16-bit logical address. The
logical address of the PLC Node is set by the local application
or by a remote node on the Powerline.
Physical addressing: Every CY8CLED16P01 has a unique
64-bit physical address.
Group addressing: This is explained in the next section.
2.3.8 Group Membership
Group membership enables the user to multicast messages to
select groups. The CY8CLED16P01 supports two types of group
addressing:
Single Group Membership – The network protocol supports up
to 256 different groups on the network in this mode. In this
mode, each PLC node can only be part of a single group. For
example, multiple PLC nodes can be part of Group 131.
Multiple Group Membership – The network protocol supports
eight different groups in this mode and each PLC node can be
a part of multiple groups. For example, a single PLC node can
be a part of Group 3, Group 4, and Group 7 at the same time.
Both of these membership modes can also be used together for
group membership. For example, a single PLC node can be a
part of Group 131 and also multiple groups such as Group 3,
Group 4, and Group 7.
The group membership ID for broadcasting messages to all
nodes in the network is 0x00.
The service type is always set to Unacknowledgment Mode in
Group Addressing Mode. This is to avoid acknowledgment
flooding on the powerline during multicast.
2.3.9 Remote Commands
In addition to sending normal data over the Powerline, the
CY8CPLC10 can also send (and request) control information to
(and from) another node on the network. The type of remote
command to transmit is set by the TX_CommandID register and
when received, is stored in the RX_CommandID register.
When a control command (Command ID = 0x01 - 0x08 and 0x0C
- 0x0F) is received, the protocol will automatically process the
packet (if Lock_Configuration is '0'), respond to the initiator, and
notify the host of the successful transmission and reception.
When the send data command (ID 0x09) or request for data
command (ID 0x0A) is received, the protocol will reply with an
acknowledgment packet (if TX_Service_Type = '1'), and notify
the host of the new received data. If the initiator doesn't receive
the acknowledgment packet within 500ms, it will notify the host
of the no acknowledgment received condition.
When a response command (ID 0x0B) is received by the initiator
within 1.5s of sending the request for data command, the
protocol will notify the host of the successful transmission and
reception. If the response command is not received by the
initiator within 1.5s, it will notify the host of the no response
received condition.
The host is notified by updating the appropriate values in the
INT_Status register (including Status_Value_Change).
The command IDs 0x30-0xff can be used for custom commands
that would be processed by the external host (e.g. set an LED
color, get a temperature/voltage reading). The available remote
commands are described in Table 2-3 on page 6 with the
respective Command IDs.
Field
Name
No. of
Bits
Tag
Description
SA Type
1
Source
Address
Type
0 – Logical Addressing
1 – Physical Addressing
DA Type
2
Destination
Address
Type
00 – Logical Addressing
01 – Group Addressing
10 – Physical Addressing
11 – Invalid
Service
Type
1
0 – Unacknowledged Messaging
1 – Acknowledged Messaging
Response
1
Response
0 - Not an acknowledgement or
response packet
1 - Acknowledgement or response
packet
Seq Num
4
Sequence
Number
4-bit unique identifier for each
packet between source and desti-
nation.
Header
CRC
4
4-bit CRC value. This enables the
receiver to suspend receiving the
rest of the packet if its header is
corrupted
相關(guān)PDF資料
PDF描述
CYW2332BCI PLL FREQUENCY SYNTHESIZER, 1200 MHz, QCC24
CYW255OXC 255 SERIES, LOW SKEW CLOCK DRIVER, 24 TRUE OUTPUT(S), 0 INVERTED OUTPUT(S), PDSO48
CYW256OXCT 256 SERIES, LOW SKEW CLOCK DRIVER, 12 TRUE OUTPUT(S), 0 INVERTED OUTPUT(S), PDSO28
D01-9970121 SIP1, IC SOCKET
D01-9974842 SIP48, IC SOCKET
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
CY8CLED16P01-28PVXIT 功能描述:LED照明片上系統(tǒng)- SoC PROGRAMMABLE W/EZ 32K FLASH 2K RAM RoHS:否 類型:Power Programmable SoC Power Controllers 最大時(shí)鐘頻率:48 MHz 程序存儲(chǔ)器大小:16 KB 數(shù)據(jù) RAM 大小:1 KB 數(shù)據(jù) ROM 大小:2 KB 接口:API, DALI, DMX512, I2C, SPI, UART, USB 可編程輸入/輸出端數(shù)量:14 片上 ADC:6 x 12-bit 片上 DAC:6 x 8-bit 電源電流:16 mA 電源電壓:7 V to 32 V 封裝 / 箱體:QFN-56 封裝:Tray 制造商:Cypress Semiconductor 核心:M8C 數(shù)據(jù)總線寬度:8 bit 程序存儲(chǔ)器類型:Flash 定時(shí)器數(shù)量:8 x 32-bit 高電平輸出電流:10 mA 低電平輸出電流:25 mA 最大工作溫度:+ 85 C 最小工作溫度:- 40 C 安裝風(fēng)格:SMD/SMT
CY8CLED16P01-48LFXI 功能描述:LED照明片上系統(tǒng)- SoC 32 KB 2048 B RoHS:否 類型:Power Programmable SoC Power Controllers 最大時(shí)鐘頻率:48 MHz 程序存儲(chǔ)器大小:16 KB 數(shù)據(jù) RAM 大小:1 KB 數(shù)據(jù) ROM 大小:2 KB 接口:API, DALI, DMX512, I2C, SPI, UART, USB 可編程輸入/輸出端數(shù)量:14 片上 ADC:6 x 12-bit 片上 DAC:6 x 8-bit 電源電流:16 mA 電源電壓:7 V to 32 V 封裝 / 箱體:QFN-56 封裝:Tray 制造商:Cypress Semiconductor 核心:M8C 數(shù)據(jù)總線寬度:8 bit 程序存儲(chǔ)器類型:Flash 定時(shí)器數(shù)量:8 x 32-bit 高電平輸出電流:10 mA 低電平輸出電流:25 mA 最大工作溫度:+ 85 C 最小工作溫度:- 40 C 安裝風(fēng)格:SMD/SMT
CY8CLED16P01-48LTXI 功能描述:可編程片上系統(tǒng) - PSoC PROGRAMMABLE W/EZ 32K FLASH 2K RAM RoHS:否 制造商:Cypress Semiconductor 核心:8051 處理器系列:CY8C36 數(shù)據(jù)總線寬度:8 bit 最大時(shí)鐘頻率:67 MHz 程序存儲(chǔ)器大小:32 KB 數(shù)據(jù) RAM 大小:4 KB 片上 ADC:Yes 工作電源電壓:0.5 V to 5.5 V 工作溫度范圍:- 40 C to + 85 C 封裝 / 箱體:QFN-68 安裝風(fēng)格:SMD/SMT
CY8CLED16P01-48LTXIT 功能描述:可編程片上系統(tǒng) - PSoC Powerline Comm Sol 32K Flash 2K Ram RoHS:否 制造商:Cypress Semiconductor 核心:8051 處理器系列:CY8C36 數(shù)據(jù)總線寬度:8 bit 最大時(shí)鐘頻率:67 MHz 程序存儲(chǔ)器大小:32 KB 數(shù)據(jù) RAM 大小:4 KB 片上 ADC:Yes 工作電源電壓:0.5 V to 5.5 V 工作溫度范圍:- 40 C to + 85 C 封裝 / 箱體:QFN-68 安裝風(fēng)格:SMD/SMT
CY8CLEDAC01 功能描述:LED照明驅(qū)動(dòng)器 EZ Color RoHS:否 制造商:STMicroelectronics 輸入電壓:11.5 V to 23 V 工作頻率: 最大電源電流:1.7 mA 輸出電流: 最大工作溫度: 安裝風(fēng)格:SMD/SMT 封裝 / 箱體:SO-16N