4015插針咪頭 針長1.5H 普通 振膜式

批發(fā)數(shù)量 50-9999PCS 10000-99999PCS ≥100000PCS
梯度價格 0.25 0.24 0.23
型號
TY-4015-MIC-1.5H
品牌
TY
加工定制
種類
傳聲器(咪頭)
類型
振膜式
材質(zhì)
銅、錫
規(guī)格尺寸
40*15(mm)
聲道數(shù)
準(zhǔn)立體聲
靈敏度
-42±3dB
頻率響應(yīng)
300HZ-3KHZ
輸出阻抗
≤2.2KΩ
針長
1.5mm
規(guī)格
普通




 

 


 
(1) Vibration Test振動試驗
       To be no interference in operation after vibrations, 10Hz to 50Hz for 2 ho-urs full amplitude 1.52mm ,the sensitivity to be within ±3dB from initial sens-itivity,the measurement should be done  after 3 hours at the room temperature.
       將沒有操作干擾過的咪頭,在10HZ到50HZ、1.52 mm全振幅下振動 30分鐘后,試驗后在常溫下放置3小時后測試,靈敏度變化在±3dB內(nèi)。
(2) Drop Test跌落試驗
       The microphone without packaged must be subjected to each 3 drops at three axises from 
theheight of 120cm to 2cm thick hardwood board, the sensitivity to be within ±3dB from initial 
sensitivity,the measurement should be done  after 3 hours at the room temperature.
       不帶包裝的咪頭經(jīng)過從3個不同的軸面從120厘米的高度下落到2厘米厚的硬質(zhì)木板上,試驗后在常溫下放置3小時后測試,靈敏度變化在±3dB內(nèi)。
(3) High Temperature Test高溫試驗
       To be no interference in operation after high temperature test 70±3℃ for 48 hours. The
 sensitivity to be within ±3dB from initial sensitivity, the mea-surement should be done  after 3 hours at the room temperature.
      將沒有操作干擾過的咪頭在70±3℃高溫下試驗48小時,試驗后在常溫下放置3小時后測試,靈敏度變化在±3dB內(nèi)。
(4) Isotherm & ISO-humidity Test恒溫恒濕試驗
       To be no interference in operation after storage test at temperature 55±3℃ and relative 
humidity (95±3%) for 48 hours, the sensitivity to be within ±3dB from initial sensitivity, the
 measurement should be done  after 3 hours at   the room temperature.
       將沒有操作干擾過的咪頭在溫度55±3℃、相對濕度95±3%的環(huán)境下試驗48小時,試驗后在常溫下放置3小時后測試,靈敏度變化在±3dB內(nèi) 。
(5) Low Temperature Test 低溫試驗
        To be no interference in operation after Low temperature test -25±3℃ for 48 hours, the sensitivity to be within ±3dB from initial sensitivity,the meas-urement should be done  after 3 hours at the room temperature.
        將沒有操作干擾過的咪頭在-25±3℃的低溫環(huán)境下放置48小時,試驗后在常溫下放置3小時后測試,靈敏度變化在±3dB內(nèi) 。
(6) Temperature Cycle Test溫度循環(huán)試驗
        To be no interference in operation after exposure at +65±2℃ for 0.5 hour,
at 20±2℃ for 1 hour, at 25±2℃ for 0.5 hour,  at 20±2℃ for 10 minutes, with 5 cycles.
 The sensitivity to be within ±3dB from initial sensitivity 
       將沒有操作干擾過的咪頭在+65±2℃下0.5小時,后在20±2℃下10分鐘,后在-25±2℃下0.5小時,后在20±2℃下10分鐘,連續(xù)循環(huán)5次,試驗后在常溫下放置3小時后測試,靈敏度變化在±3dB內(nèi) 。